A device for simultaneous measurement of pressure and shear force distribution on the plantar surface of the foot

  • Brian Davis
  • , Julie E. Perry
  • , Donald C. Neth
  • , Kevin C. Waters
  • Cleveland Clinic Foundation

Research output: Contribution to journalArticlepeer-review

54 Scopus citations

Abstract

A device has been designed to simultaneously measure the vertical pressure and the anterior-posterior and medial-lateral distributed shearing forces under the plantar surface of the foot. The device uses strain gauge technology and consists of 16 individual transducers (each with a surface area measuring 2.5 x 2.5 cm) arranged in a 4 x 4 array. The sampling frequency is 37 Hz and data may be collected for 2 s. The device was calibrated under both static and dynamic conditions and revealed excellent linearity (±5%), minimal hysteresis (±7.5%), and very good agreement between applied and measured loads (±5%). Vector addition of the distributed loads gave resultant forces that were qualitatively very similar to those obtained from a standard force plate. Data are presented for measurements from the forefoot of 4 diabetic subjects during the initiation of gait, demonstrating that distributed shear and pressure on the sole of the foot can be measured simultaneously. A device has been designed to simultaneously measure the vertical pressure and the anterior-posterior and medial-lateral distributed shearing forces under the plantar surface of the foot. The device uses strain gauge technology and consists of 16 individual transducers (each with a surface area measuring 2.5×2.5 cm) arranged in a 4×4 array. The sampling frequency is 37 Hz and data may be collected for 2 s. The device was calibrated under both static and dynamic conditions and revealed excellent linearity (±5%), minimal hysteresis (±7.5%), and very good agreement between applied and measured loads (±5%). Vector addition of the distributed loads gave resultant forces that were qualitatively very similar to those obtained from a standard force plate. Data are presented for measurements from the forefoot of 4 diabetic subjects during the initiation of gait, demonstrating that distributed shear and pressure on the sole of the foot can be measured simultaneously.
Original languageEnglish
Pages (from-to)93-104
Number of pages12
JournalJournal of Applied Biomechanics
Volume14
Issue number1
DOIs
StatePublished - Jan 1 1998

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Diabetic foot
  • Instrumentation
  • Plantar pressure
  • Shear measurement

Cite this