TY - JOUR
T1 - Fluorescent Labeling Can Alter Polymer Solution Dynamics
AU - McDonough, Ryan
AU - Cueto, Rafael
AU - Phillies, George D. J.
AU - Russo, Paul S.
AU - Dorman, Derek
AU - Streletzky, Kiril A
PY - 2015/9/17
Y1 - 2015/9/17
N2 - There is a widespread assumption that modest chemical modification of a large polymer molecule, by adding a fluorescent label or the like, has no significant effect on polymer solution dynamics. We here report that light tagging of hydroxypropylcellulose (HPC) with fluorescein dye has a significant effect on the dynamic behavior of the chains, as measured using fluorescence photobleaching recovery (FPR) and dynamic light scattering (DLS). We compared unprocessed HPC, HPC processed in preparation for chemical modification, and HPC chemically modified by tagging with a fluorescein moiety. Addition of covalently bound fluorescein to the polymer eliminates the ultraslow (D ≈ 10-10 cm2/s) relaxational mode found with DLS in the unlabeled HPC samples. Our findings explain the perceived discrepancies between DLS and FPR studies of HPC solutions. The discrepancies arise from differences in sample preparation. Comparison of FPR spectra (which measure the single particle diffusion process) and DLS spectra (which measure the relative motions of pairs of particles), each with its own intrinsic time and distance scales, provides insight into the nature of diffusion and the state of dissolution in dilute and nondilute HPC solutions.
AB - There is a widespread assumption that modest chemical modification of a large polymer molecule, by adding a fluorescent label or the like, has no significant effect on polymer solution dynamics. We here report that light tagging of hydroxypropylcellulose (HPC) with fluorescein dye has a significant effect on the dynamic behavior of the chains, as measured using fluorescence photobleaching recovery (FPR) and dynamic light scattering (DLS). We compared unprocessed HPC, HPC processed in preparation for chemical modification, and HPC chemically modified by tagging with a fluorescein moiety. Addition of covalently bound fluorescein to the polymer eliminates the ultraslow (D ≈ 10-10 cm2/s) relaxational mode found with DLS in the unlabeled HPC samples. Our findings explain the perceived discrepancies between DLS and FPR studies of HPC solutions. The discrepancies arise from differences in sample preparation. Comparison of FPR spectra (which measure the single particle diffusion process) and DLS spectra (which measure the relative motions of pairs of particles), each with its own intrinsic time and distance scales, provides insight into the nature of diffusion and the state of dissolution in dilute and nondilute HPC solutions.
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84944081063&origin=inward
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=84944081063&origin=inward
U2 - 10.1021/acs.macromol.5b01669
DO - 10.1021/acs.macromol.5b01669
M3 - Article
SN - 0024-9297
VL - 48
SP - 7245
EP - 7255
JO - Macromolecules
JF - Macromolecules
IS - 19
ER -